We're professional RMU & GIS(SF6 & SF6 Free) Accessories manufacturers and suppliers in China, specialized in providing high quality RMU & GIS(SF6 & SF6 Free) Accessories with competitive price. To buy or OEM RMU & GIS(SF6 & SF6 Free) Accessories from our factory. For free sample, contact us now.

RMU & GIS(SF6 & SF6 Free) Accessories

0
  • Sf6 Upper Support for Sf6 Circuit Breaker

    1.Name: Insulators
    2.Material: Epoxy Resin
    3.Maximum Voltage: 10kv~40.5kv
    4.Usage: Insulation, Switchgear
    5.Connection Method: Trough Type

  • The Insulation Component of GIS Lower Support

    1.Application: Insulators
    2.Material: Epoxy Resin
    3.Maximum Voltage: 10kv~40.5kv
    4.Usage: Insulation, Switchgear
    5.Connection Method: Trough Type

  • Cable Boots Cable Bushing Cable Front Plug

    1.8.7/15kV detachable cable terminal is suitable for electric system 15kV-630A and below ratings.
    2.It is widely used for RMU's XLPE power cable incoming and outgoing terminal and connects with the switchgear's bushing.
    3.It is also applicable to all kinds of cable distribution boxes and box type transformer station device.
    4.The connecting bushing conforms to the C size (large-small end ¢56-¢ 46, length 90 mm, inner hole M16) in the standard of EN50880&5018.
    5.The product's performance can meet with IEC60502, IEC61442 and GB/T12706.

  • 12kV Silastic Cable End Protection Cap

    1. The European-style insulation protection cap is used for sealing up spare bushing to ensure the safety of people and safe operation of equipment.
    2. The 630 A insulation cap provides insulation protection for 630 A living bushing connector, and provides protection against dust and moisture when the bushing is not living.
    3.Reliably connect the grounding wire of protection cap to the system grounding point.
    4.Clean the inner wall of protection cap with clean paper, then evenly apply grease. The same treatment is applied to the connection surface of the bushing socket.
    5.The installation must be performed with system is complete power-off.

  • 12kV Fuse Insulated Cylinder for Gas Tank

    1.Power frequency withstand voltage: 48/79kV/1min
    2.Partial discharge experiment: 13.2kV≤5PC
    3.Material: Epoxy Resin

  • Fuse Insulated Cylinder for Sf6 Circuit Breaker

    1.Fuse insulated cylinder
    2.Type: SF6-12/437
    3.Rated voltage: 12kV

  • Epoxy Resin Sf6 Fuse Insulated Cylinder

    1.Epoxy Resin Sf6 Fuse Insulated Cylinder for Gas Insulated Switchgear
    2.12kV/24kV embedded fuse insulated cylinder for SF6 gas tank of ABB type and others
    3.RMU fuse holder

  • 24kV Embedded Fuse Cylinder Holder for RMU

    1.12kV/24kV embedded fuse insulated cylinder for SF6 gas tank of ABB type and others
    2.RMU fuse holder
    3.Power frequency withstand voltage 79kV/imin
    4.Partial discharge expenment: 13.2kV≤5Pc

  • Busbar Connector Base for Sf6 Circuit Breaker

    1.Rated Voltage: 12kV
    2.Material: Epoxy Resin
    3.Application: Insulators
    4.Model NO.:SF6-12/95

  • 12kV 24kV Sf6 Housing Gas Tank

    1.Product No.: HCA803
    2.Name: SF6 Upper Housing
    3.Outline dimension: 700×330×170

  • Solid Insulation for Solid Insulated Switchgear

    1.Product name: cable cone
    2.Type: GLZ01-A/B/C-12
    3.Rated current: 630A

  • Circuit Breaker for Gas Insulated Switchgear

    1.Rated voltage:12kV.
    2. Altitude above sea level: no more than 2000m, earthquake intensity not exceed 8 degrees.
    3. Ambient temperature: Max. Temperature: +50ºC, Min. Temperature: -45ºC. Average relative humidity daily: ≤95%, average relative humidity monthly: ≤90%.
    4. It should be installed in condition without obvious dust, fire, chemical erosion, explosion, vapor and salt spray.
    5. Rated SF6 gas pressure: 0.04mPa. SF6 gas meets the requirements of GB/T 12022-2014 "Industrial sulfur hexafluoride"